This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Jiayin JYPC-2 Electromagnetic Solenoid Water Pump. This miniature electromagnetic pump is designed for various applications requiring precise fluid transfer, such as in carpet cleaners, electric irons, steam mops, garment steamers, and coffee machines. Please read this manual thoroughly before installation or use.

2. Təhlükəsizlik Məlumatı

  • Elektrik Təhlükəsizliyi: Enerji təchizatının nasosun həcminə uyğun olduğundan əmin oluntage (AC 110-120V, 60Hz). Disconnect power before installation, maintenance, or troubleshooting.
  • Maye Uyğunluğu: Use only with water or non-corrosive liquids. Using corrosive liquids can damage the pump and void the warranty.
  • Temperatur Limitləri: Adhere to specified working temperatures: ambient temperature (Ta) up to 70°C (158°F) and medium temperature (Tf) up to 60°C (140°F).
  • Quraşdırma: Ensure proper and secure installation to prevent leaks or disconnections.
  • Professional quraşdırma: Hər hansı quraşdırma addımından əmin deyilsinizsə, ixtisaslı bir texniklə məsləhətləşin.

3. Məhsul bitdiview

The Jiayin JYPC-2G is a compact electromagnetic solenoid pump designed for reliable and consistent fluid delivery. Its robust construction ensures durability and efficient performance in various household and commercial appliances.

Jiayin JYPC-2G Electromagnetic Solenoid Water Pump

Şəkil 3.1: Ön view of the Jiayin JYPC-2G electromagnetic solenoid water pump. This image displays the pump's main body, the red solenoid coil housing, the white plastic inlet/outlet nozzles, and the electrical terminals. The product label with specifications like "Jiayin JYPC-2 AC110V-120V 16W 60Hz" is clearly visible.

Bucaqlı view of Jiayin JYPC-2G pump showing electrical terminals and hose connections

Şəkil 3.2: Bucaqlı view of the Jiayin JYPC-2G pump. This perspective highlights the two flat electrical terminals at the bottom, the white plastic inlet nozzle on the left, and the black plastic outlet nozzle on the right. The red solenoid housing and the silver metal casing are also visible.

4. Spesifikasiyalar

Refer to the table below for detailed technical specifications of the JYPC-2G pump.

Jiayin JYPC-2G pump with technical drawings and specifications table

Şəkil 4.1: Hərtərəfli view of the JYPC-2G pump including its physical dimensions, technical parameters, and performance graphs. The image shows the pump itself, a detailed technical drawing with measurements, a table listing specifications like voltage, frequency, power, maximum pressure, average flow, and noise level, and three graphs illustrating flow/pressure, flow/time, and temperature rise/time characteristics.

ParametrDəyər
ModelJYPC-2G
NövMiniature Electromagnetic Pump
CildtageAC 110-120V
Tezlik60Hz
Güc16W
Maksimum axın sürəti500 ± 10% cc/min
İş təzyiqi1.5 bar
İşləyən OrtaWater or non-corrosive liquid
Ətraf mühitin temperaturu (Ta)Max 70°C (158°F)
Medium Temperature (Tf)Max 60°C (140°F)
MaterialPlastic (housing), Copper, Steel (internal components)
Ölçülər (təxminən)3.5"U x 1.6"W x 3.5"H
Çəki4.1 oz (116q)
Səs-küy Səviyyəsi45 dB

5. Quraşdırma və Quraşdırma

Before beginning installation, ensure the power supply is disconnected from the appliance where the pump will be installed.

  1. Identify Inlet and Outlet: The pump typically has a clear or white plastic nozzle for the inlet and a black or darker nozzle for the outlet. Refer to the product images for visual identification.
  2. Şlanq bağlantısı: Securely connect the appropriate hoses to the pump's inlet and outlet nozzles. Ensure connections are tight to prevent leaks. For the flow test method, a 13.8-inch silicon tube with an outer diameter of 0.28 inch and an inner diameter of 0.146 inch is connected to the water inlet port.
  3. Elektrik bağlantısı: Connect the pump's two electrical terminals to the appliance's power supply (AC 110-120V, 60Hz). Ensure correct polarity if specified by the appliance, though for AC pumps, polarity is often not critical. Secure all electrical connections.
  4. Montaj: Mount the pump securely within the appliance. Ensure it is stable and not subject to excessive vibration.
  5. Sızma yoxlaması: After installation, perform a visual inspection for any loose connections or potential leak points before restoring power.
Yan view of Jiayin JYPC-2G pump showing hose connections

Şəkil 5.1: Yan view of the Jiayin JYPC-2G pump. This image clearly shows the white plastic inlet nozzle on the left and the black plastic outlet nozzle on the right, indicating the direction of fluid flow. The red solenoid housing is also visible.

6. Əməliyyat Təlimatları

The Jiayin JYPC-2G pump operates automatically when power is supplied, typically controlled by the appliance it is integrated into.

  1. Güc Aktivdir: Once installed and all connections are secure, restore power to the appliance.
  2. Fluid Supply: Ensure there is an adequate supply of the intended liquid (water or non-corrosive liquid) available at the pump's inlet.
  3. Aktivləşdirmə: The pump will activate when the appliance's control system signals it to operate, initiating fluid transfer.
  4. Monitorinq: Observe the pump's operation during its first use to ensure proper function and no leaks.

The pump is designed for continuous operation (ED100%) within its specified temperature limits.

7. Baxım

Regular maintenance helps ensure the longevity and optimal performance of your pump.

  • Təmizləmə: Periodically inspect the pump and connections for any buildup or debris. Clean the exterior with a damp parça. Pompanı suya batırmayın.
  • Maye keyfiyyəti: Always use clean, non-corrosive liquids to prevent internal clogging or damage.
  • Bağlantı yoxlanışı: Regularly check hose and electrical connections for tightness and signs of wear or damage.
  • Yaddaş: If the appliance is to be stored for an extended period, ensure the pump is drained of any liquid to prevent freezing or stagmillət.

8. Giderme

This section addresses common issues you might encounter with the Jiayin JYPC-2G pump.

ProblemMümkün SəbəbHəll
Nasos işləmirNo power supply; Loose electrical connections; Faulty pump.Check power source and appliance controls. Verify electrical connections are secure. If power is present and connections are good, the pump may need replacement.
No fluid flow or weak flowInsufficient fluid supply; Clogged inlet/outlet; Air in the system; Kinked hose; Pump malfunction.Ensure adequate fluid in the reservoir. Check hoses for clogs or kinks. Bleed air from the system if necessary. Inspect pump for internal blockages.
Əlaqələrdən sızmaLoose hose connections; Damaged hoses; Improperly seated seals.Hortumu sıxın clamps or connections. Inspect hoses for cracks or damage and replace if necessary. Ensure seals are correctly seated.
Əməliyyat zamanı qeyri-adi səs-küyAir in the system; Debris in pump; Loose mounting.Bleed air from the system. Disconnect power and inspect for debris (if accessible and safe). Ensure the pump is securely mounted.

If troubleshooting steps do not resolve the issue, contact customer support or a qualified technician.

9. Zəmanət və Dəstək

For warranty information or technical support, please refer to the documentation provided with your original appliance or contact the manufacturer of the appliance in which this pump is installed. As this is a component part, specific warranty terms may be covered by the end product's warranty.

For further assistance, you may also contact the seller directly through the platform where the purchase was made.

© 2024 Jiayin. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.