The RM7 rackmount kit is a collection of parts that, once installed, configure the 7 Series Performance Oscilloscope for mounting into a standard 19-inch wide equipment rack. The slides will also fit racks of 20-36 inch depth.

Hissələrin siyahısı
Remove all parts from the box and check that all items are present and match the parts in Table 1.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (1)Rackmount kit parts and replaceable parts list

Tövsiyə olunan alətlər

  • T25 Torx driver, long
  • Phillips tornavida
  • 3/8 inch nut driver or socket wrench
  • 11/32 inch nut driver or socket wrench
  • 3 mm altıbucaqlı açar

Məclis
Assemble the RM7 rackmount kit parts as described here. The kit parts are noted in the procedure with the associated number shown in the kit parts diagram.

  1. Remove all items from the box and compare them to the parts list.
  2. Gather the tools needed to assemble the rack. (See Recommended tools.)
  3. Remove the four side handles from the instrument (two per side). Use a T25 Torx driver to remove the 4 screws that secure each handle to the instrument. Set the screws and handles aside for later.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (2)
  4. Set the rack tray (5) upside down on a bench.
  5. Store the handles under the rackmount tray:
    • a. Remove the two handle storage brackets (8) from the tray by removing the six nuts using a 3/8 inch nut driver.
    • b. Remove the two handle storage brackets (8) from the tray by removing the six nuts using a 3/8 inch nut driverTektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (3)
    • c. Mount two instrument handles to each handle storage bracket, ensuring that the bracket threads are opposite the handle (see image)Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (4)
    • d. Re-attach the handle storage brackets to the underside of the rackmount tray using the six nutsTektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (5)
  6. Remove the two side rails from the sides of the tray (4):
    • a. Cut the tie-wraps that hold the rails in place for shipping.
    • b. Push the rack slides back until they click into the tray tabsTektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (6)
    • c. Depress the tab to release and unlock the slide.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (7)
    • d. Remove the slide.
  7. Install the two side rails into the rack.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (8)
    • a. Orient the rail in the rack so that the short adjustable bracket on the rail is at the front of the rack.
    • b. Use an 11/32 socket driver and a Phillips screw driver to loosen the nuts on the rail assembly and adjust the rail length to fit the rack depth. The nut locations are shown in the above figure.
    • c. If the rack is >24 inches, remove one or two of the front-most screws on the rail. This allows you to extend the rail beyond 24 inches. If the rail is <24 in., proceed to step 7d.
    • d. Use the provided 10-32 in. screws to secure the front and rear rail ends to the rack. Do not fully tighten them. They will be tightened after placing the tray into the rack in step 8.
    • e. Use an 11/32 socket driver and a Phillips screw driver to tighten the nuts on the rail sides, fixing the rail length.
  8. Install the tray into the rack.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (9)
    • a. Place the tray into the rails. You will hear the tabs in the rails click when it is installed.
    • b. Depress the rail tabs to unlock the tray and slide the tray all the way into the rack. XƏBƏRDARLIQ: Use a screwdriver to depress the rail tabs. Finger pinch hazard. Ensure your fingers do not get caught in the rail.
    • c. Tighten the four 10-32 screws that attach the rail to the rear of the rack.
    • d. Slide the tray halfway out, then tighten the 10-32 screws that secure the rails to the front of the rack.
    • e. Slide the tray in and out to ensure it slides smoothly. Adjust the rails as needed.

Quraşdırma
Install the 7 Series Performance Oscilloscope into the RM7 assembly and instrument rack. The kit parts are noted in the procedure with the associated number shown in the kit parts diagram. This procedure explains how to install the instrument into the rack with the RM7 tray assembly already installed. The instrument is heavy, so adhere to the following safety precautions.

XƏBƏRDARLIQ:
Personal injury can occur when lifting and moving the instrument into the rack. The instrument is heavy. Use a 2-person lift to move the instrument.

XƏBƏRDARLIQ:
Finger pinch hazard. Ensure your fingers do not get caught between the instrument and the tray when placing the instrument into the tray assembly. The instrument is heavy and can cause injury to the fingers if they are caught between the instrument and the tray.

XƏBƏRDARLIQ:
Tip hazard. Secure the rack against tipping. Do not leave the rails fully extended with the instrument loaded. The instrument is heavy and can tip the rack if the rack is not fully secured against tipping.

  1. Install the top bracket (7) onto the instrumentTektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (10)
    • a. Place the top bracket over the top of the instrument and align it with the screw holes on either side. You will need to flex the bracketto get it to fit on the instrument.
      b. Secure the bracket to the instrument with four M5 screws using a 3 mm Hex key
  2. Slide out the secured tray assembly from the rack until it clicks. This means it is fully extended.
  3. Place the instrument onto the tray.
    XƏBƏRDARLIQ:
    Tip hazard. Secure the rack against tipping. Do not leave the rails fully extended with the instrument loaded. The instrument is heavy and can tip the rack if the rack is not fully secured against tipping.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (11)
    • a. Note the slots in the tray for the instrument feet.
    • b. Lift the instrument with two people.
    • c. Tip the display up slightly and carefully place the instrument onto the tray, rear feet first. The instrument feet will fit into the tray slots.
    • d. Lower the front of the instrument slowly and adjust the grip to avoid pinching fingers.
  4. Secure the instrument to the tray from the bottom using four M5 screws.Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (12)Tektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (13)
  5. Depress the rail tabs to unlock the tray and slide the instrument all the way into the rack.
    XƏBƏRDARLIQ: Use a screwdriver to depress the rail tabs. Finger pinch hazard. Ensure your fingers do not get caught in the rail
  6. Secure the instrument to the rackTektronix-RM7-7-Series-DPO-Performance-Oscilloscope-FIG (14)
    • a. Secure the top brackets to the rack using four 10-32 screws.
    • b. Secure the tray to the rack using two 10-32 screws
  7. Ensure adequate ventilation when the instrument is in the rack as follows:
    • a. 60 mm of clearance for the side inlets.
    • b. ≥ 27 mm of clearance in the rear fan exhaust area.
    • c. 20 mm of clearance for the front bottom inlet on the bottom of the instrument. Ensure the front rack venting is not blocked and that the ambient temperature inside the rack, near the air inlets on both sides and the bottom of the instrument, does not
    • 40 °C-dən çox.

DİQQƏT:
Risk of instrument damage if the instrument air inlets or front rack venting are blocked. Ensure adequate ventilation when the instrument is in a rack and that the front rack venting is not blocked. Ensure the ambient temperature inside the rac,k near the air inlets on both sides and the bottom of the instrument, does not exceed 40 °C

İndi qeydiyyatdan keçin!

  • Məhsulunuzu qorumaq üçün aşağıdakı linki vurun.
  • tek.com/register
  • *P071380801*
  • 071-3808-01 January 2025
  • Copyright © 2025, Tektronix. 2025 Bütün hüquqlar qorunur. Lisenziyalı proqram məhsulları Tektronix və ya onun törəmə şirkətləri və ya təchizatçılarına məxsusdur və milli müəllif hüquqları qanunları və beynəlxalq müqavilə müddəaları ilə qorunur. Tektronix məhsulları ABŞ və xarici patentləri əhatə edir, buraxılmış və gözləməkdədir. Bu nəşrdəki məlumatlar əvvəllər dərc edilmiş bütün materiallardakı məlumatları əvəz edir. Spesifikasiyalar və qiymət dəyişikliyi imtiyazları qorunur. İstinad edilən bütün digər ticarət adları müvafiq şirkətlərin xidmət nişanları, ticarət nişanları və ya qeydə alınmış ticarət nişanlarıdır.

TEKTRONIX və TEK, Tektronix, Inc -in qeydə alınmış ticarət nişanlarıdır.

  • Şirkət Adı Tektronix, Inc.
  • 14150 SW Karl Braun Sürücü
  • Poçt qutusu 500
  • Beaverton, OR 97077

US
For product information, sales, service, and technical support, visittek.com ərazinizdəki kontaktları tapmaq üçün. Zəmanət məlumatı üçün ziyarət edin
tek.com/warranty

Tez-tez verilən suallar

Q: Can this rackmount kit be used with other oscilloscopes models?

A: The RM7 rackmount kit is specifically designed for use with the 7 Series DPO Performance Oscilloscope and may not be compatible with other models.

Q: What is the warranty coverage for the RM7 Rackmount kit?

A: For warranty information, please visit tek.com/warranty or contact Tektronix directly for more details on warranty coverage for this product.

Sənədlər / Resurslar

Tektronix RM7 7 Series DPO Performance Oscilloscope [pdf] Təlimat kitabçası
RM7 7 Series DPO Performance Oscilloscope, RM7, 7 Series DPO Performance Oscilloscope, 7 Series DPO, Performance Oscilloscope, Performance, Oscilloscope

İstinadlar

Şərh buraxın

E-poçt ünvanınız dərc olunmayacaq. Tələb olunan sahələr qeyd olunub *