1. Giriş
This manual provides essential information for the safe and efficient operation of your Steinbach SPS 75-1 Filter Pump. This self-priming pump is designed for use with pool filter systems, capable of handling pools up to 33,000 liters. It features a robust 230 V/450 W motor and a pump capacity of 8,520 liters per hour (142 l/min).
Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the unit or injury.
2. Təhlükəsizlik Təlimatları
Yanğın, elektrik cərəyanı və ya yaralanma riskini azaltmaq üçün həmişə aşağıdakı təhlükəsizlik tədbirlərinə əməl edin.
- Elektrik Təhlükəsizliyi: Ensure the pump is connected to a properly grounded outlet. Do not operate the pump with a damaged power cord or plug. Disconnect power before performing any maintenance or service.
- Su temperaturu: The pump is designed for a maximum water temperature of 35°C (95°F). Operating above this temperature can cause damage to the pump.
- Yerləşdirmə: Install the pump on a stable, level surface, away from direct sunlight and excessive moisture. Ensure adequate ventilation around the motor.
- Uşaqlar və ev heyvanları: Əməliyyat zamanı uşaqları və ev heyvanlarını nasosdan uzaq tutun.
- Baxım: Only perform maintenance as described in this manual. For complex repairs, consult a qualified technician.
3. Quraşdırma
Follow these steps for proper installation of your filter pump.
- Qablaşdırma: Carefully remove all components from the packaging. Inspect the pump for any signs of damage during transit.
- Yerləşdirmə: Position the pump as close to the pool as possible, ensuring it is below the water level for optimal self-priming. The pump should be on a firm, level surface to prevent vibration.
- Hortum Bağlantıları: Connect the pool hoses to the pump's inlet and outlet ports. The pump supports hose diameters of 32mm and 38mm. Ensure all connections are tight to prevent leaks and maintain prime.

Şəkil 3.1: Yaxından view of the pre-filter inlet with a hose connection, showing the clear cover and filter basket.

Figure 3.2: The pre-filter inlet without a hose attached, illustrating the threaded connection for secure fitting.

Figure 3.3: The pump's outlet connection with a hose securely fastened, ready for water discharge.

Figure 3.4: The pump's outlet port, showing the internal threading for hose attachment.

Figure 3.5: An overall perspective of the Steinbach SPS 75-1 Filter Pump, highlighting its compact design and key components.
- Pompanın doldurulması: As a self-priming pump, it will draw water once connected. However, for initial startup, it is recommended to fill the pre-filter housing with water to assist in faster priming.
- Elektrik bağlantısı: Plug the pump into a suitable 230V electrical outlet. Ensure the circuit is protected by a Residual Current Device (RCD) for safety.
4. Əməliyyat Təlimatları
Once installed, operating the pump is straightforward.
- Pompanın işə salınması: Turn on the power supply to the pump. The pump will begin to draw water and circulate it through your filter system.
- Monitorinq: Observe the pump during its initial operation to ensure there are no leaks and that water is flowing correctly. The pump operates at approximately 70 dB.
- Pompanın dayandırılması: Pompanın enerji təchizatını söndürün.
- İş vaxtı: The optimal run time for your pump depends on your pool size and usage. For a 33,000-liter pool, ensure sufficient daily filtration to maintain water clarity.
5. Baxım
Regular maintenance ensures the longevity and efficiency of your pump.
- Filtrdən əvvəl təmizləmə: The pump is equipped with a pre-filter to catch larger debris. Regularly inspect and clean the pre-filter basket. To do this, turn off the pump, disconnect power, unscrew the clear lid, remove the basket, clean it, and reassemble. Ensure the O-ring is properly seated for a watertight seal.
- Qışlama: Before freezing temperatures, drain all water from the pump and hoses. Store the pump in a dry, frost-free location.
- Ümumi təmizləmə: Keep the exterior of the pump clean and free from dirt and debris. Do not use harsh chemicals.
6. Giderme
If you encounter issues with your pump, refer to the following common problems and solutions.
| Problem | Mümkün Səbəb | Həll |
|---|---|---|
| Pompa işə düşmür | Enerji təchizatı yoxdur Motorun həddindən artıq yüklənməsi Pervane tıxandı | Elektrik bağlantısı və elektrik kəsicisini yoxlayın Mühərrikin soyumasına icazə verin, maneələri yoxlayın Inspect and clear impeller |
| Aşağı su axını | Ön filtr tıxandı Emiş xəttində hava sızması Hovuzda suyun aşağı səviyyəsi | Clean pre-filter basket Bütün əlaqələri sıxlıq üçün yoxlayın Hovuza su əlavə edin |
| Nasos səs-küylüdür | Sistemdə hava Vibrasiya Aşınmış podşipniklər | Sistemdən havanı çıxarın, sızma olub olmadığını yoxlayın Ensure pump is on a stable surface İxtisaslı texniki ilə əlaqə saxlayın |
| Nasos işini itirir | Emiş xəttində hava sızması Su səviyyəsinin aşağı olması Ön filtr tıxandı | Check all connections and O-rings Ensure adequate water level Clean pre-filter basket |
Bu həlləri sınadıqdan sonra problem davam edərsə, lütfən, müştəri dəstəyi və ya ixtisaslı xidmət texniki ilə əlaqə saxlayın.
7. Spesifikasiyalar
Technical data for the Steinbach SPS 75-1 Filter Pump.

Figure 7.1: Product label detailing the pump's electrical and performance specifications.

Figure 7.2: Dimensional drawing of the pump, indicating height, width, and length.
| Parametr | Dəyər |
|---|---|
| Model nömrəsi | 040920 |
| Cildtage | 230 V |
| Güc | 450 Vt |
| Nasos Tutumu | 8,520 l/h (142 l/min) |
| Max. Pump Height | 9 m |
| Bağlantı diametri | 32/38 mm |
| Maksimum Su Temperaturu | 35°C |
| Maximum Pool Size | 33,000 litr |
| Səs-küy Səviyyəsi | təqribən. 70 dB |
| Məhsulun Ölçüləri (U x G x Y) | 45 x 20.5 x 25 sm |
| Maddə Çəkisi | 6 kq |
| Material | plastik |
| Güc mənbəyi | Kabelli Elektrik |
8. Zəmanət və Dəstək
Specific warranty details for this product are not provided in this manual. Please refer to your purchase documentation or the manufacturer's official webzəmanət məlumatı üçün sayt.