1. Məhsul bitdiview
The Aermec PXAI Control Panel is an electronic thermostat designed for precise control of fan coil units. It offers both thermostatic and continuous ventilation modes, making it suitable for various HVAC applications, including 2-pipe and 4-pipe systems.

Şəkil 1: Ön view of the Aermec PXAI Control Panel, a white electronic thermostat with two large rotary knobs and several indicator lights and smaller buttons. The Aermec logo is visible at the top.
Əsas Xüsusiyyətlər:
- On-Board Fan Coil Installation: Designed for direct installation on the fan coil unit.
- Automatic / Manual Season Change: Allows for flexible control of heating and cooling modes.
- Control of Up to 2 ON/OFF Valves: Manages water flow to the fan coil for efficient temperature regulation.
- Internal Water (2.5 m) and Air (2.5 m) Probes: Ensures accurate temperature sensing for optimal performance.
- Fin Management and External Contact: Provides advanced control capabilities for integrated systems.
2. Quraşdırma və Quraşdırma
The Aermec PXAI Control Panel is designed for wall mounting. Professional installation is recommended to ensure proper functionality and safety.
2.1. Quraşdırmadan əvvəl yoxlanış siyahısı:
- Ensure power to the fan coil unit is disconnected at the main breaker.
- Verify compatibility with your fan coil system (2-pipe or 4-pipe).
- Confirm the power supply is 230 Volts.
- Have necessary tools: screwdriver set, wire strippers, drill (if mounting plate not pre-installed).
2.2. Mounting the Control Panel:
- Carefully remove the front cover of the control panel to access mounting holes.
- Position the control panel on the wall or fan coil unit where it will be installed. Mark the drilling points.
- Drill pilot holes if necessary and secure the backplate of the control panel using appropriate screws.
- Ensure the panel is level and securely fastened.
2.3. Naqil birləşmələri:
Refer to the wiring diagram provided with your specific fan coil unit and the PXAI control panel for detailed connection instructions. Ensure all connections are secure and comply with local electrical codes.
- 230V enerji təchizatını təyin olunmuş terminallara qoşun.
- Connect the fan speed control wires.
- Connect the valve control wires (up to 2 ON/OFF valves).
- Connect the internal water and air probes.
- Connect any external contacts or fin management wires as required by your system.
Əhəmiyyətli: All wiring should be performed by a qualified electrician. Incorrect wiring can cause damage to the unit or pose a safety hazard.
3. Əməliyyat Təlimatları
The Aermec PXAI Control Panel features mechanical knobs for intuitive operation.
3.1. Yandırma/Söndürmə:
- Locate the main power switch or knob on the control panel.
- Turn the knob to the "OFF" position to power down the unit.
- Turn the knob to the "AUTO" or desired fan speed setting to power on the unit.
3.2. Temperatur nəzarəti:
- Use the temperature setting knob to adjust the desired room temperature. Rotate clockwise to increase temperature, counter-clockwise to decrease.
- The thermostat will automatically regulate the fan coil operation to maintain the set temperature.
3.3. Fan sürətinə nəzarət:
- The fan speed knob allows you to select different fan speeds (e.g., Low, Medium, High) or an "AUTO" mode.
- In "AUTO" mode, the fan speed adjusts automatically based on the temperature difference from the set point.
- For continuous ventilation, select a specific fan speed setting.
3.4. Season Change (Heating/Cooling):
- The control panel supports automatic or manual season change.
- In Avtomatik rejim, the system detects the water temperature in the pipes (via the internal water probe) and automatically switches between heating and cooling modes.
- In Əl rejimi, you may need to manually select heating or cooling via a dedicated switch or setting, if available on your specific model. Refer to the specific markings on your control panel.
4. Baxım
The Aermec PXAI Control Panel requires minimal maintenance. Regular cleaning and occasional checks will ensure its longevity and optimal performance.
4.1. Təmizləmə:
- Before cleaning, ensure the control panel is powered off.
- İdarəetmə panelinin səthini yumşaq, d ilə silinamp parça.
- Do not use abrasive cleaners, solvents, or excessive water, as these can damage the unit.
4.2. Dövri yoxlamalar:
- Periodically check that all knobs and buttons operate smoothly.
- Ensure there are no obstructions around the air temperature sensor (usually small vents on the panel) to allow for accurate readings.
- If the unit is connected to a battery (e.g., for memory backup), check the battery status if applicable (refer to the full product manual for battery details).
Qeyd: For maintenance of the fan coil unit itself (e.g., filter cleaning, coil cleaning), refer to the fan coil unit's specific user manual.
5. Giderme
This section provides solutions to common issues you might encounter with your Aermec PXAI Control Panel.
| Problem | Mümkün Səbəb | Həll |
|---|---|---|
| Control panel not powering on. | No power supply; loose wiring; internal fuse blown. |
|
| Fan coil not responding to temperature settings. | Incorrect mode selected; faulty temperature probe; fan coil issue. |
|
| Fan not operating at selected speed. | Fan coil motor issue; wiring problem; fan speed setting. |
|
If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Aermec customer support or a certified HVAC technician.
6. Texniki spesifikasiyalar
| Xüsusiyyət | Detal |
|---|---|
| Model Adı | Pannello di Comando PXAI Aermec. Termostato elettronico per ventilconvettori completo di sonde. (Aermec PXAI Control Panel Electronic Thermostat for Fan Coils complete with probes) |
| Brend | Aermec |
| İstehsalçı | Aermec |
| Məhsul növü | Electronic Thermostat for Fan Coils |
| Havalandırma Nəzarəti | Thermostatic or Continuous |
| Sistem Uyğunluğu | 2-pipe systems, 4-pipe systems |
| Valf Nəzarəti | Up to 2 ON/OFF valves |
| Problar Daxildir | Internal Water Probe (2.5 m), Internal Air Probe (2.5 m) |
| Enerji təchizatı | 230 Volt (AC) |
| Power Type (as per spec) | Batareya (Likely for memory/backup, not primary operation given 230V supply) |
| Quraşdırma növü | Divar montajı |
| Nəzarətçi növü | Mexanik Düymə |
| Ölçülər (Y x G x D) | 14.8 sm x 7.0 sm x 2.75 sm |
7. Zəmanət və Dəstək
Specific warranty information for the Aermec PXAI Control Panel is typically provided at the point of purchase or within the product packaging. Please retain your proof of purchase for warranty claims.
7.1. Zəmanət Məlumatı:
Aermec products are generally covered by a manufacturer's warranty against defects in materials and workmanship. The duration and terms of the warranty may vary by region and product. For detailed warranty terms, please refer to the documentation included with your product or visit the official Aermec websayt.
7.2. Müştəri dəstəyi:
For technical assistance, troubleshooting, or service requests, please contact Aermec customer support. You can typically find contact information (phone numbers, email, or support portal) on the official Aermec websaytda və ya məhsul sənədlərinizdə.
Dəstək ilə əlaqə saxlayarkən, lütfən, aşağıdakı məlumatları hazırlayın:
- Product Model: Aermec PXAI Control Panel
- Satınalma tarixi
- Məsələnin ətraflı təsviri
Qeyd: Unauthorized repairs or modifications may void your warranty. Always seek assistance from qualified personnel.





