Hubbell 7051-G

HUBBELL 7051-G Receptacle Instruction Manual

Model: 7051-G | 15A, 125V-AC, 2-Pole, 3-Wire

Giriş

This manual provides essential instructions for the safe installation, operation, and maintenance of the Hubbell 7051-G 15A, 125V-AC, 2-Pole, 3-Wire Receptacle. Please read this manual thoroughly before installation and retain it for future reference. Proper installation by a qualified electrician is recommended.

Təhlükəsizlik Məlumatı

XƏBƏRDARLIQ: Risk of electric shock or fire. Improper installation can result in serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. Use only copper wire with this device. Do not use with aluminum wire unless specifically rated for it. Ensure all connections are tight and secure.

  • Always disconnect power before working on electrical circuits.
  • Quraşdırma prosesinin hər hansı bir hissəsinə əmin deyilsinizsə, ixtisaslı elektrikçi ilə məsləhətləşin.
  • Bütün yerli və milli elektrik kodlarına əməl edin.
  • Do not exceed the specified electrical ratings of the device.

Məhsul Bitdiview

The Hubbell 7051-G is a 15 Amp, 125 Volt, 2-pole, 3-wire grounding duplex receptacle designed for general-purpose electrical applications. It features a durable nylon construction and is suitable for various residential and commercial installations.

Ön view of Hubbell 7051-G Receptacle

Şəkil: Ön view of the Hubbell 7051-G duplex receptacle, showing two outlets with grounding slots.

Quraşdırma və Quraşdırma

Tələb olunan alətlər: Screwdriver (Phillips and/or flathead), Wire Strippers, Voltage Tester.

  1. Gücü söndürün: Locate the circuit breaker or fuse that controls the outlet you are working on and turn it off. Verify power is off using a voltage tester.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the receptacle out and disconnect the wires.
  3. Tellər hazırlayın: Strip approximately 1/2 inch of insulation from the ends of the circuit wires. Ensure the wire ends are clean and straight.
  4. Yan view of Hubbell 7051-G Receptacle with strip gauge

    Şəkil: Yan view of the Hubbell 7051-G receptacle, showing the strip gauge for proper wire preparation.

  5. Telləri birləşdirin:
    • Green or Bare Copper Wire (Ground): Connect to the green grounding screw.
    • Ağ Tel (neytral): Connect to the silver screw.
    • Black or Red Wire (Hot/Live): Connect to the brass screw.
    Ensure wires are securely wrapped around the screws in a clockwise direction and tightened firmly.
  6. Geri view of Hubbell 7051-G Receptacle showing wiring terminals

    Şəkil: Geri view of the Hubbell 7051-G receptacle, illustrating the screw terminals for wiring connections (brass for hot, silver for neutral, green for ground).

    Close-up of Hubbell 7051-G Receptacle back with wiring details

    Image: Close-up of the rear of the Hubbell 7051-G receptacle, detailing the wire strip gauge and voltage ratings (15A, 125V and 10A, 250V).

  7. Quraşdırma qəbuledicisi: Carefully push the wired receptacle back into the electrical box. Secure it with the provided mounting screws.
  8. Divar plitəsini quraşdırın: Attach the decorative wall plate over the receptacle.
  9. Gücü bərpa edin: Turn the power back on at the circuit breaker or fuse box. Test the receptacle with a known working device.

Əməliyyat Təlimatları

To operate the Hubbell 7051-G receptacle, simply insert the plug of your electrical device into one of the two available outlets. Ensure the plug is fully inserted. The receptacle is designed for standard 2-prong or 3-prong grounded plugs.

Ön view of Hubbell 7051-G Receptacle

Şəkil: Ön view of the Hubbell 7051-G receptacle, ready for device plugs.

Baxım

The Hubbell 7051-G receptacle requires minimal maintenance. Periodically inspect the receptacle and wall plate for any signs of damage, cracks, or discoloration. If any damage is observed, turn off power at the circuit breaker and replace the receptacle immediately. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.

Problemlərin aradan qaldırılması

  • No Power at Receptacle:
    • Check the circuit breaker or fuse for the circuit. Reset the breaker or replace the fuse if tripped/blown.
    • Ensure all wire connections are secure. Turn off power before checking connections.
    • Qabın həcmini sınayıntage tester to confirm power presence.
  • Boş Fiş Bağlantısı:
    • If plugs do not stay firmly in the receptacle, the internal contacts may be worn. The receptacle should be replaced by a qualified electrician.
  • Həddindən artıq istiləşmə:
    • If the receptacle feels warm to the touch, immediately disconnect all devices and turn off power. This could indicate an overload or a faulty connection. Consult a qualified electrician.

Spesifikasiyalar

BrendHubbell
Model7051-G
Amptəmizləmək15 Amps
Cildtage125 volt
Dirəklər/tellər2-Pole, 3-Wire Grounding
MaterialNeylon
Məhsul Ölçüləri4.25 x 2 x 1.5 düym
İstehsalçıHUBBELL
Hubbell 7051-G Receptacle in its original packaging

Image: The Hubbell 7051-G receptacle shown in its original product box.

Barcode label for Hubbell 7051-G Receptacle

Image: Barcode label for the Hubbell 7051-G 2P 3W 15A 125V-AC Receptacle, showing product identification details including UPC 0129190665219.

Zəmanət və Dəstək

Specific warranty information for the Hubbell 7051-G Receptacle is not provided within this manual. For warranty details or technical support, please contact Hubbell customer service directly or visit their official websayt. Satınalma qəbzini alışın sübutu olaraq saxlayın.

İstehsalçı: HUBBELL

Websayt: www.hubbell.com (Misamplink, faktiki link fərqli ola bilər)

Əlaqədar Sənədlər - 7051-G

Preview Trinetics UltraVac Solid Dielectric Motor Operated Vacuum Switches: Installation and Operation Instructions
Comprehensive installation and operation guide for Trinetics UltraVac Solid Dielectric Motor Operated Vacuum Switches by Hubbell. Covers product specifications, dimensions, electrical connections, safety warnings, handling, and maintenance.
Preview IWS-ZP-3P Occupancy Sensor Installation and Adjustment Guide
Comprehensive installation and adjustment guide for the Hubbell IWS-ZP-3P occupancy sensor, detailing wiring, timing, sensitivity, and photocell settings for optimal performance.
Preview Hubbell Omni PBX Heat Pump Water Heater: Operation and Installation Manual
Comprehensive operation and installation manual for the Hubbell Omni PBX Heat Pump Water Heater, covering safety, installation guidelines, operation, maintenance, troubleshooting, and warranty information.
Preview Hubbell Twist-Lock 50A Grounding Receptacle & Flanged Inlet Installation Guide
Official installation instructions from Hubbell for Twist-Lock 50A grounding receptacles and flanged inlets. Covers wiring, mounting, and safety precautions for qualified electricians.
Preview Hubbell Tipi AVR Alüminium Şaquli Break Keçid Xüsusiyyətləri
Hubbell Tipi AVR Alüminium Şaquli Qırma açarı üçün ətraflı spesifikasiyalar və konfiqurasiyalar, o cümlədən məhsul haqqında məlumat, xüsusiyyətlər, aksesuarlar, yük kəsmə cihazları və nömrələmə ardıcıllığı.
Preview Hubbell OMNI PBX Heat Pump Water Heater Operating and Maintenance Manual
Comprehensive operating and maintenance manual for the Hubbell OMNI PBX heat pump water heater, covering installation, operation, troubleshooting, and warranty information.