VEVOR SDC-20A

VEVOR 12V 20A DC/DC Battery Charger SDC-20A User Manual

Model: SDC-20A

1. Giriş

The VEVOR 12V 20A DC/DC Battery Charger SDC-20A is designed to efficiently charge your auxiliary battery from your vehicle's primary battery while driving. This intelligent charger is compatible with a wide range of 12V battery types, including lead-acid, lithium, AGM, GEL, and flooded batteries. It is an ideal solution for maintaining optimal charge in backup batteries for RVs, commercial vehicles, and boats, ensuring your power needs are met on the go.

2. Təhlükəsizlik Təlimatları

Please read and understand all safety instructions before installing or operating the charger. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Məhsul bitdiview

3.1 Əsas Xüsusiyyətlər

3.2 Komponentlər

The VEVOR SDC-20A charger features robust construction and clearly marked connection points.

VEVOR SDC-20A DC/DC Battery Charger showing input/output terminals and DIP switches

Şəkil: Ön view of the VEVOR SDC-20A DC/DC Battery Charger, highlighting the input/output terminals, cooling vents, and DIP switches for battery type selection. The image also illustrates the charger's high efficiency, indicating it charges 2X faster than standard 10A chargers, reaching a maximum of 20A.

Üst view of VEVOR SDC-20A DC/DC Battery Charger with model label

Şəkil: Üst view of the VEVOR SDC-20A DC/DC Battery Charger, clearly displaying the product label with model number SDC-20A, system voltage 12-12V, charging current 20A, and maximum output power 250W.

4. Spesifikasiyalar

ParametrDəyər
ModelSDC-20A
Giriş həcmitage12V (DC 8V-16V)
Doldurma cərəyanı20A
Maksimum Çıxış Gücü250W
Uyğun batareya növləriLead-acid (SLA), Lithium (LiFePO4), AGM, GEL, Flooded (FLD)
Casing MaterialAlüminium ərintisi
Əməliyyat temperaturu-20°C - 50°C (4°F - 122°F)
Xalis Çəki1.22 kq (2.69 funt)
Məhsul Ölçüləri16.26 x 14.48 x 8.38 sm (6.5 x 5.7 x 3.3 düym)
Lead-acid Charging Voltage Menzil13.2V-14.7V
Lithium Charging Voltage Menzil12.6V-14.6V

5. Quraşdırma və Quraşdırma

Proper installation is crucial for the safe and efficient operation of your VEVOR DC/DC charger.

5.1 Şarj cihazının quraşdırılması

VEVOR SDC-20A DC/DC Battery Charger installed in a van with dimensions

Image: Diagram showing the VEVOR SDC-20A DC/DC Battery Charger installed in a van, illustrating its compact size and ease of integration into a vehicle's electrical system. Dimensions are provided: 6.5 inches (165mm) length, 5.7 inches (145mm) width, and 3.3 inches (83mm) height.

5.2 Naqil birləşmələri

Refer to the wiring diagram for correct connections. Always use appropriate fuses for protection.

Wiring diagram for VEVOR SDC-20A DC/DC Battery Charger showing isolated input and output

Image: Wiring diagram illustrating the smart battery protection feature with completely isolated input and output. It shows the connection from the starter battery (DC Input) to the charger, and from the charger (DC Output) to the standby battery, with fuses on both input and output lines.

  1. Giriş bağlantısı: Connect the positive (+) terminal of the starter battery to the charger's input positive terminal. Connect the negative (-) terminal of the starter battery to the charger's input negative terminal. Install a suitable fuse (e.g., 30A for 20A charger) on the positive input line, as close to the starter battery as possible.
  2. Çıxış Bağlantısı: Connect the positive (+) terminal of the auxiliary battery to the charger's output positive terminal. Connect the negative (-) terminal of the auxiliary battery to the charger's output negative terminal. Install a suitable fuse (e.g., 30A for 20A charger) on the positive output line, as close to the auxiliary battery as possible.
  3. Ignition Wire (D+): For automatic operation, connect the D+ terminal on the charger to a switched ignition source (e.g., D+ terminal on the alternator or an ignition-controlled relay) that provides 12V when the engine is running. This ensures the charger only operates when the vehicle is running.

5.3 Battery Type Selection (DIP Switches)

The charger features DIP switches to select the correct battery type for optimal charging. Refer to the table below and the diagram on the charger for the correct settings.

VEVOR SDC-20A DC/DC Battery Charger showing compatibility with multiple battery types

Image: The VEVOR SDC-20A DC/DC Battery Charger connected to a 12V battery, illustrating its compatibility with various 12V battery types including Lithium (LI), Sealed Lead-Acid (SLA), AGM, GEL, and Flooded (FLD) batteries. This image emphasizes the charger's versatility in providing optimal charging curves for different battery chemistries.

Batareya növüDIP Switch SettingŞarj Voltage Menzil
Lityum (LiFePO4)Refer to charger label12.6V-14.6V
Lead-acid (SLA, AGM, GEL, Flooded)Refer to charger label13.2V-14.7V

Note: The exact DIP switch positions for each battery type are typically printed on the charger's label or in a dedicated diagram within the physical manual. Ensure you set these correctly before operation.

6. Əməliyyat Təlimatları

Once properly installed and configured, the VEVOR SDC-20A charger operates automatically.

6.1 Avtomatik doldurma

6.2 Multi-Stage Doldurma Prosesi

The charger employs an intelligent multi-stage charging algorithm to optimize battery health and lifespan.

Ağıllı multi-stage charging curve for VEVOR SDC-20A DC/DC Battery Charger

Image: Graph illustrating the intelligent multi-stage charging process (Bulk, Absorption, Float) for lead-acid batteries. It shows rapid charging in the bulk phase, stable current in the absorption phase, and a weak current maintenance in the float phase until the battery is fully charged.

6.3 Litium Batareyasının Aktivləşdirilməsi

The charger includes a feature to activate deeply discharged or inactive lithium batteries.

VEVOR SDC-20A DC/DC Battery Charger activating a lithium battery

Image: Visual representation of the VEVOR SDC-20A DC/DC Battery Charger's ability to 'wake up' a lithium battery, restoring low-voltage batteries to extend their lifespan and boost performance.

If a lithium battery is deeply discharged below its protection voltage, the charger can attempt to activate it by applying a low current until the voltage rises to a safe level for normal charging to resume.

7. Baxım

Regular maintenance ensures the longevity and optimal performance of your charger.

8. Giderme

If you encounter issues with your charger, refer to the following common troubleshooting steps:

ProblemMümkün SəbəbHəll
Charger not operatingNo D+ signal; Blown fuse; Loose connections; Input voltage çox aşağı.Check D+ connection and ensure engine is running; Inspect and replace fuses; Tighten all wiring connections; Verify starter battery voltage is within operating range (8V-16V).
Slow charging or low outputIncorrect battery type setting; High resistance in wiring; Auxiliary battery deeply discharged.Verify DIP switch settings match battery type; Check wire gauge and connections for resistance; Allow more time for charging, especially for deeply discharged batteries.
Həddindən artıq istiləşməPoor ventilation; Overload; Faulty cooling fan.Ensure adequate airflow around the charger; Check for obstructions to cooling fans; Reduce load if possible; Contact support if fan is faulty.
Error indicator (if present)Overvoltagetage, reverse polarity, short circuit.Giriş/çıxış həcmini yoxlayıntages; Verify correct polarity of connections; Inspect for any short circuits. Disconnect and reconnect to reset.

If the problem persists after following these steps, please contact VEVOR customer support.

9. Zəmanət və Dəstək

VEVOR products are designed for reliability and performance. For technical support, warranty information, or to register your product for an e-warranty certificate, please visit the official VEVOR support websayt:

www.vevor.com/support

Please have your model number (SDC-20A) and purchase details ready when contacting support.