BSEED W-SD Multi Function Power Meter

əsas funksiya

Məhsulun təqdimatı
The multi – functional Wlfl guide rail meter adopts a rail – type design, which is small in size, compact instructure and simple in installation; it uses an LCD display screen to display current, voltage, electricity, power,frequency and other electrical parameters, is convenient for users to acquire data and easy to operate. It hasgood anti – electromagnetic interference capabilities, meets various needs of power management, facilitates therealizationof terminal – intelligent power metering, and facilitates the retrofitting of power meters in the lateltransformation of the lighting system. It is widely used in commercial squares, science and technology parksuniversities and other occasions where billing is required, It can also be jointly deployed with energyconsumption monitoring and energy management systems. its application scope includes property bilingmanagement, electricity metering, power demand – side management, energy management andenergy-saving analysis, Other low – voltage power systems, etc.
Texniki parametrlər
| Nominal cildtage | AC 220V/110v |
| Əməliyyat həcmitage sıra | AC 80V-300V |
| Tezlik | 50/60Hz |
| Güc diapazonu | 0-99999 kVt/saat |
| Zamanlama diapazonu | 0-999 gün |
| Güc faktoru | 0-1.0PF |
| Temperatur diapazonu | -40-150°C |
| Overvoltage təyin aralığı | 130-300V |
| Undervolvoltage təyin aralığı | 75-21ov |
| Overcurrent setting range | 1-63A |
| Overpower setting range | 1-15KVt |
| Nominal izolyasiya həcmitage | 400V |
| Çıxış kontaktları | 1NO |
| Mexanik həyat | 10,000 dəfə |
| Mühafizə sinfi | lp30 |
| Hündürlük | ::,2000m |
| Rütubət | 550%at40°C(non-condensing) |
Function Introduction, Default Settings
| Seçimlər | Ayar aralığı | Defolt parametrlər |
| Overvoltage
müdafiə |
230-300V | 270V |
| Undervolvoltage
müdafiə |
110-21ov | 170V |
| Həddindən artıq cərəyan
müdafiə |
0.1-63A | 40A |
| Həddindən artıq yükdən qorunma | 1-15KVt | 8. 8KW |
| Elektrik enerjisi
müdafiə |
0-99999 kVt/saat | 99999 kVt / saat |
| Xarici dövr
müdafiə |
0-150°( | 85°C |
| Number of closures | 1-30 dəfə | 5 dəfə |
| Closingtime | 1-600 saniyə | 30 saniyə |
| Electricityclearing | Yandır/Söndür | off |
| Timing clearing | Yandır/Söndür | off |
| Power-up operation | Close/open/hold | saxlamaq |
| Overvoltagedelay
müdafiə |
1-600 sec/off | off |
| Undervolvoltagedelay
müdafiə |
1-600 sec/off | off |
| Overcurrent delay
müdafiə |
1-600 sec/off | off |
| Overloaddelay
müdafiə |
1-600 sec/off | off |
| Xarici dövr
delayprotection |
1-600 sec/off | off |
structural analysis

ÖLÇÜLƏR
Məhsul Ölçüsü

Naqil diaqramı

Set function operation
Press the set key for 5 seconds to enter the settings page, give an example of the “Overvoltage Protection” setting, click the
key cursor to move to the “Overvoltage Protection” position, press the set key to select, press the
key to adjust to the required value, press the set to save after the adjustment is completed, and press the
key to select other settings. If you do not need to set it, press the
key to move the cursor to the exit position, and then press set to return to the home page. The other settings can be the same as the “Overvoltage Protection” setting method.
Set function operation
Smart Life APP proqramını yükləyin
or Graffiti APP Smart Connection
WIFI connection or reset operation method: Long press the wifi key 5-10s wifi indicator light will flash, turn on the phone Bluetooth, then open the Smart Life APP, click “+” in the upper right corner, select “Add Device”, wait for the device to scan out the device, click on the device to select the wifi name, enter the password to wait for the device to be added successfully.
ƏTRAFLI MƏLUMAT

Sənədlər / Resurslar
![]() |
BSEED W-SD Multi Function Power Meter [pdf] Təlimat kitabçası wifi_1p_din_rail, W-SD Multi Function Power Meter, W-SD, Multi Function Power Meter, Function Power Meter, Power Meter, Meter |