Elitech-loqosu

Elitech RC-5 Temperatur Ölçüsü

Elitech-RC-5-Temperature-Logger-product

Bitdiview

The RC-5 series is used to record the temperature/humidity of foods, medicines, and other goods during storage, transportation, and in each stage of the cold chain, including cooler bags, cooling cabinets, medicine cabinets, refrigerators, laboratories, reefer containers, and trucks. RC-5 is a classic USB temperature data logger used in a wide range of applications around the world. RC-5+ is an upgraded version that adds the functions, including automatic PDF reports generation, repeat start without configuration, etc.

Elitech-RC-5-Temperature-Logger-fig- (1)

  1. USB portu
  2. Sağ Düymə
  3. LCD ekran
  4. Batareya qapağı
  5. Sol Düymə

Spesifikasiyalar

Elitech-RC-5-Temperature-Logger-fig- (2)

At ultralow temperature, the LCD is slow but does not affect normal logging. It will be back to normal after the temperature rises.

  • TXT YALNIZ Windows üçün

Əməliyyat

Batareyanın aktivləşdirilməsi

  1. Batareya qapağını açmaq üçün saat yönünün tersinə çevirin.Elitech-RC-5-Temperature-Logger-fig- (3)
  2. Batareyanı yerində saxlamaq üçün yavaşca basın, sonra batareya izolyator zolağını çəkin.
  3. Batareya qapağını saat yönünə çevirin və bərkidin.

Proqram təminatını quraşdırın

Please download and install the free ElitechLog software (macOS and Windows) from Elitech.
ABŞ: www.elitechustore.com/pages/download or Elitech
Böyük Britaniya: www.elitechonline.co.uk/softwareor Elitech
BR: www.elitechbrasil.com.br.

Parametrləri konfiqurasiya edin
First, connect the data logger to the computer via USB cable, wait until Elitech-RC-5-Temperature-Logger-fig- (4) the icon shows on the LCD; then configure via:

ElitechLog Software

  • If you do not need to change the default parameters (inthe  Appendix), please click Quick Reset under the Summary menu to synchronize local time before usage;
  • Parametrləri dəyişdirmək lazımdırsa, lütfən, Parametr menyusuna klikləyin, üstünlük verdiyiniz dəyərləri daxil edin və konfiqurasiyanı tamamlamaq üçün Parametri Saxla düyməsini sıxın.

Xəbərdarlıq! For first-time users or after battery replacement:

  • To avoid time or time zone errors, please make sure you click Quick Reset or Save Parameter before usage, to sync and configure your local time into the logger.

Girişə başlayın

Düyməni basın
Press and hold the button for 5 seconds until the icon shows on the LCD, indicating the logger starts logging.

Elitech-RC-5-Temperature-Logger-fig- (5)

Auto Start (RC-5+/TE only)
Immediate Start: The logger starts logging after being removed from the computer.
Timed Start: The logger starts counting after being removed from the computer; it will start logging automatically after the set date/time.
Qeyd: If the icon keeps flashing, it means the logger is configured with a start delay; it will start logging after the set delay time elapses.

Mark Events (RC-5+/TE only)
Double-click the right button to mark the current temperature and time, up to 10 groups of data. After marking, it will be indicated by Log X on the LCD screen (X means the marked group).

Girişi dayandırın

Elitech-RC-5-Temperature-Logger-fig- (6)

  • Press Button*: Press and hold the button for 5 seconds until the icon shows on the LCD, indicating the logger stops logging.
  • Auto Stop: When the logging points reach the maximum memory points, the logger will stop automatically.
  • Use Software: Open ElitechLog software, click the Summary menu, and then the Stop Logging button.
    Qeyd: *The Default stop is via the Press Button; if set as disabled, the button’s stop function will be Invalid; please open the ElitechLog software and click the Stop Logging button to stop it.

Məlumatı yükləyin

Elitech-RC-5-Temperature-Logger-fig- (7)

  • Connect the data logger to your computer via USB cable, wait until the icon Elitech-RC-5-Temperature-Logger-fig- (4)& shows on the LCD; then download via:
  • ElitechLog Software: The logger will auto-upload data to ElitechLog, then please click Export to select your desired file ixrac etmək üçün format.
  • If data failed for auto-upload, please manually click Download and then follow the export operation.
  • Without ElitechLog Software (RC-5+/TE only): Simply find and open the removable storage
  • Device ElitechLog, save the auto-generated PDF report to your computer for viewing.

Logger-dən yenidən istifadə edin

  • To reuse a logger, please stop it first, then connect it to your computer and use ElitechLog.
  • Software to save or export the data.
  • Next, reconfigure the logger by repeating the operations in 3. Configure Parameters*
  • After finishing, follow the 4 steps of art logging to restart the logger for new logging.
  • Warning! * To make space for new loggings, all previous logging data inside the logger will be deleted after re-configuration.
  • If you forgot to save/export data, please try to locate the logger in the History menu of ElitechLoq software.

Repeat Start (RC-5+/TE only)
To restart the stopped logger, you may press and hold the left button to start logging quickly without reconfiguration. Please back up data before restarting by repeating step 7. Download Data – Download via ElitechLog Software.

Vəziyyət göstəricisi

Düymələr

Elitech-RC-5-Temperature-Logger-fig- (8)

LCD ekran

Elitech-RC-5-Temperature-Logger-fig- (9)

  1. Batareya Səviyyəsi
  2. Giriş nöqtələri
  3. Dayandı
  4. Siqnal yoxdur / Müvəffəqiyyət İşarəsi
  5. Giriş
  6. Zəngli / İşarəsiz
  7. Başlanmayıb
  8. ay
  9. PC-yə qoşulub
  10. W Day
  11. Yüksək temperatur siqnalı
  12. Maksimum dəyər
  13. Aşağı Temperatur Siqnal
  14. Minimum Dəyər

LCD interfeysi

Elitech-RC-5-Temperature-Logger-fig- (10)

Batareyanın dəyişdirilməsi

Elitech-RC-5-Temperature-Logger-fig- (11)

  1. Batareya qapağını açmaq üçün saat yönünün tersinə çevirin.
  2. Yeni və geniş temperaturlu CR2032 düymə batareyasını + tərəfi yuxarıya baxaraq batareya bölməsinə quraşdırın.
  3. Batareya qapağını saat yönünə çevirin və bərkidin.

Nə Daxildir

  • Data Logger x1
  • İstifadəçi təlimatı x1
  • Kalibrləmə Sertifikatı x 1
  • Button Battery x 1

Xəbərdarlıq

  • Xahiş edirəm oduncağınızı otaq temperaturunda saxlayın.
  • Xahiş edirəm istifadə etməzdən əvvəl batareya bölməsindəki batareya izolyator zolağını çəkin.
  • İlk dəfə istifadəçilər üçün: sistem vaxtını sinxronlaşdırmaq və konfiqurasiya etmək üçün ElitechLog proqram təminatından istifadə edin.
  • Qeyd edərkən batareyanı qeydiyyatdan götürməyin.
  • The LCD will be auto off after 15 seconds of inactivity (by default). Press the button again to turn on the screen.
  • Any parameter configuration on the ElitechLog software will delete all logged data inside the logger.
  • Please save data before you apply any new configurations.
  • Batareya nişanının yarısından az olduğu təqdirdə, uzun məsafələrə nəql etmək üçün ağacdan istifadə etməyinElitech-RC-5-Temperature-Logger-fig- (12)

Əlavə

Defolt Parametrlər

Elitech-RC-5-Temperature-Logger-fig- (13)

Sənədlər / Resurslar

Elitech RC-5 Temperatur Ölçüsü [pdf] İstifadəçi Təlimatı
RC-5, RC-5 Temperatur Qeydiyyatçısı, Temperatur Qeydiyyatçısı, Qeydiyyatçı

İstinadlar

Şərh buraxın

E-poçt ünvanınız dərc olunmayacaq. Tələb olunan sahələr qeyd olunub *