ENTTEC 73539 DIN PIXIE
Məhsul haqqında məlumat
Xüsusiyyətlər:
- Xüsusi Protokol Yaratma Bələdçisi
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Məhsuldan İstifadə Təlimatları
Giriş:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Quraşdırma tələbləri:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
UYĞUN FİRMA PROQRAMI
Fərdi protokol yaradılması aşağıdakı ENTTEC piksel kontrollerlərində təqdim olunur:
| SKU | Məhsul | Proqram təminatı versiyası |
| 73539 | DIN PIXIE | V2.0 və ya yuxarı |
| 70067 | PIXELATOR MINI | V2.0 və ya yuxarı |
| 70068 | PIXELATOR MINI MK2 | V1.0 və ya yuxarı |
| 71521 | OCTO MK2 | V4.0 və ya yuxarı |
| 71522 | OCTO MK3 | V1.0 və ya yuxarı |
GİRİŞ
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Bu funksiya istifadəçilərə səsi tənzimləməyə imkan verirtagməlumat ötürmə metodu dəstəklənən protokollarımızdan hər hansı birinə uyğun gələrsə, dəstəklənən protokollara əsaslanan e vaxt.
- Bu sənəd fərdi piksel protokolu yaratmaq və meyarları yoxlamaq üçün quraşdırma təlimatlarını təqdim edir.
QURULUM TƏLƏBLƏRİ
Fərdi protokol yaratmaq üçün aşağıdakılar tələb olunur:
- Məlumat vərəqi: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Cihaz: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
XÜSUSİ PROTOKOL YARATILMASI ÜÇÜN TƏLƏBƏR
Bu xüsusiyyət istifadəçilərə məlumat həcmini tənzimləməyə imkan verirtage timing to meet specific protocol needs. To create a custom protocol:
- Uyğun piksel protokolu üçün məlumat cədvəlini yoxlayın.
- Fərdi protokol funksiyasını aktivləşdirmək üçün Cihazın İstifadəçi İnterfeysinə keçin.
- Piksel qurğusunun məlumat həcmini tənzimləyintagvasitəsilə e vaxtlama web istehsalçının məlumat cədvəlinə uyğun olaraq interfeys.
Addım 1: Uyğun protokol üçün məlumat cədvəlini yoxlayın
- Məlumat vərəqindən istədiyiniz protokolun məlumat ötürmə üsulunu yoxlayın.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Ən çox yayılmış üsul məlumatı əlavə bitlər olmadan ötürür (məsələn, D1-D2-D3...Dn).
Example: Məlumat WB2812B məlumat cədvəlindən götürülüb
- Bəzi protokollar, məsələn, TM1814, ön tərəfdə əlavə məlumatları ehtiva edir (məsələn, C1-C2-D1-D2…Dn).
Example: TM1814 məlumat vərəqindən götürülmüş məlumat
- Ən çox yayılmış üsul məlumatı əlavə bitlər olmadan ötürür (məsələn, D1-D2-D3...Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Cihaz tərəfindən dəstəklənən uyğunluq protokolunu təyin edin (və ya yuxarıdakı məsələn, seçinample) that shares the same data transmission method as your desired pixel protocol.
- Əlavə konfiqurasiya üçün 2-ci addıma keçin.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web interfeys
- kimi Google Chrome təklif olunur web browser to access the OCTO/PIXELATOR MINI’s web interfeys.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webProqramı yükləmək üçün www.enttec.com saytına daxil olun.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
İstədiyiniz piksel qurğusunun qoşulduğu çıxışa keçin. Açılan siyahıdan 1-ci addımda təsdiqlənmiş eyni ötürmə metodunu paylaşan piksel protokolunu seçin.
- Enable Custom protocol (Continue to Step 3)
Məlumat həcminə daxil olmaq üçün "Xüsusi" qeyd qutusunu aktivləşdirintage vaxt təyini. Fərdi protokolu deaktiv etmək üçün işarəni çıxarın.
DIN PIXIE üçün
- USB Type-B istifadə edərək DIN PIXIE-ni kompüterə qoşun.
- EMU Proqramını işə salın.
- Cihazı skan edin və aşkar edilmiş DIN PIXIE konfiqurasiyasını vurun.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
Addım 3: Fərdi cild təyin edintage vaxtlama
- Cildlə uyğunlaşıntagİstədiyiniz protokolun məlumat vərəqində e vaxtı. Xüsusi Protokol məlumat həcmini tamamlamaq üçün 4 giriş tələb edirtage vaxt tənzimlənməsi:
Cildtage Timing Definition Bit 0 Yüksək Vaxt (T0H) Cildtage kodu 0 üçün yüksək vaxt tələb olunur. Bit 1 Yüksək Vaxt (T1H) Cildtage kodu 1 üçün yüksək vaxt tələb olunur. Overall Bit Time: Ümumi cildtage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Vaxtı Sıfırlayın Ümumi cildtage hər bir məlumat toplusu arasında məlumat ötürülməsini sıfırlamaq üçün az vaxt tələb olunur. 
- Datasheet – Data voltage vaxt məlumatı Məsample
WB2818B məlumat cədvəlindən- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage vaxt diapazonu.
- Cild dolduruntage vaxt diapazonu Çıxış Parametrlərindəki xüsusi sahədə.

ƏHƏMİYYƏTLİ
- ENTTEC recommends taking the median value of the range for the start.
- Dəyişdirilmiş dəyərin qüvvəyə minməsi üçün istifadəçi parametrləri YAXŞI SAXLAMALI olacaq.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
NƏTİCƏ
- Bu təlimat uyğun ENTTEC cihazları üçün fərdi protokolun necə qurulacağını nümayiş etdirdi və istədiyiniz piksel qurğularının məlumat cədvəlini yoxlamaq üçün texniki biliklər təqdim etdi.
- Bu addımları yerinə yetirməklə, istifadəçilər texniki dəstəyi və ya yeni proqram təminatının buraxılışını gözləmədən açılan siyahıda tapılmayan xüsusi piksel protokolu yarada bilərlər. Suallarınız varsa və ya düzgün məlumatı tapmaqda çətinlik çəkirsinizsə, yerli ofislərdəki mehriban dəstək komandamızla əlaqə saxlayın.
Tez-tez verilən suallar
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web brauzer.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
Sənədlər / Resurslar
![]() |
ENTTEC 73539 DIN PIXIE [pdf] Təlimat kitabçası DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |