L3 Campus Stackable Managed Switch
"
Spesifikasiyalar
- Model: Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
LED - LED Göstərici:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
düzgün) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Məhsuldan İstifadə Təlimatları
Fəsil 2: Quraşdırma
Quraşdırma prosesinə başlamazdan əvvəl hər şeyə sahib olduğunuzdan əmin olun
the necessary tools and follow safety precautions.
- Paketin tərkibi: Check all items mentioned in
paket. - Təhlükəsizlik tədbirləri: Follow the guidelines to
təhlükəsiz quraşdırma təmin edin. - Quraşdırma Alətləri: Gather all tools required
quraşdırma üçün. - Məhsulun quraşdırılması: Addım-addım edin
instructions provided in the manual for successful
quraşdırma.
Fəsil 3: Bağlantı
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
Fəsil 4: Konfiqurasiya
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
ehtiyaclar.
Tez-tez verilən suallar
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
əlavə yardım üçün təlimatdakı bölmə.
“`
Biznes Şəbəkə Həlli
Quraşdırma Bələdçisi
Omada Campus Stackable L3 Managed Switch
Bu Quraşdırma Təlimatı haqqında
Bu Quraşdırma Təlimatında avadanlıq xüsusiyyətləri, quraşdırma üsulları və quraşdırma zamanı diqqət edilməli olan məqamlar təsvir olunur. Bu Quraşdırma Təlimatının strukturu aşağıdakı kimidir: Fəsil 1 Giriş Bu fəsil keçidin xarici komponentlərini təsvir edir. Fəsil 2 Quraşdırma Bu fəsil açarın necə quraşdırılmasını göstərir. Fəsil 3 Qoşulma Bu fəsil keçidin fiziki qoşulmasının necə ediləcəyini göstərir. Fəsil 4 Konfiqurasiya Bu fəsil keçidin konfiqurasiyasını təsvir edir. Əlavə A Problemlərin aradan qaldırılması Əlavə B Spesifikasiyaları
Tamaşaçılar
Bu Quraşdırma təlimatı:
Şəbəkə Mühəndisi
Şəbəkə administratoru
Konvensiyalar
· Some models featured in this guide may be unavailable in your country or region. For local sales information, visit https://www.omadanetworks.com/.
· 2-ci Fəsil, 3-cü və 4-cü Fəsildəki rəqəmlər yalnız nümayiş məqsədləri üçündür. Keçidiniz təsvir ediləndən görünüşünə görə fərqlənə bilər.
· PoE büdcə hesablamaları laboratoriya sınaqlarına əsaslanır. Faktiki PoE güc büdcəsinə zəmanət verilmir və müştəri məhdudiyyətləri və ətraf mühit amilləri nəticəsində dəyişəcək.
· Bu təlimat xüsusi mesajları vurğulamaq üçün xüsusi formatlardan istifadə edir. Aşağıdakı cədvəldə bu təlimatda istifadə olunan bildiriş nişanları verilmişdir.
Diqqətli olmağı unutmayın. Diqqət cihazın zədələnməsinə səbəb ola biləcək potensialı göstərir.
Xəbərdar olmağı xatırlat. Qeyddə məhsulun daha yaxşı istifadəsi üçün faydalı məlumatlar var.
Əlaqəli sənəd
Məhsulun İstifadəçi Bələdçisi və CLI İstinad Kılavuzu Yükləmə Mərkəzində verilir. Ən son məhsul məlumatlarını əldə etmək üçün məmuru ziyarət edin websayt: https://support.omadanetworks.com/document/.
İçindəkilər
Fəsil 1 Giriş ———————-- 01
1.1 Məhsul Bitdiview ……………………………………………………..01 1.2 Görünüş……………………………………………………………..01
Fəsil 2 Quraşdırma ———————- 12
2.1 Paketin məzmunu …………………………………………………….12 2.2 Təhlükəsizlik tədbirləri ……………………………………………………12 2.3 Quraşdırma Alətləri……………………………………………………………………………………………………………………………………………..14 ………………………………………………..2.4
Fəsil 3 Əlaqə ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Fəsil 4 Konfiqurasiya ——————– 27
4.1 Konfiqurasiya Bitdiview……………………………………………27 4.2 Bağımsız Rejim…………………………………………………………27 4.3 Nəzarətçi rejimi………………………………………………………28
Əlavə A Problemlərin aradan qaldırılması —————- 32
Əlavə B Spesifikasiyalar —————— 33
Omada Campus Stackable L3 Managed Switch
Fəsil 1 Giriş
1.1 Məhsul Bitdiview
Müəssisə və c üçün nəzərdə tutulmuşdurampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampBunlara şəbəkə kameralarını, simsiz LAN giriş nöqtələrini, IP telefonları, şəbəkə hublarını, quraşdırılmış kompüterləri və s. daxildir.
1.2 Görünüş
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 Port
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 Port
10G SFP+ Slot LED
Giriş 01
Omada Campus Stackable L3 Managed Switch
LED göstəricisi
PWR1*
PWR2
Yaşıl
Söndür
Yaşıl
Sarı Yandır**
Söndür
Yaşıl
Söndür
Söndür
Göstəriş
Açar PWR1 ilə təchiz edilmişdir. PWR2 bağlantısı kəsilib və ya düzgün işləmir.
Açar PWR1 ilə təchiz edilmişdir. PWR1 və PWR2 qoşulub.*
Açar PWR2 ilə təchiz edilmişdir. PWR1 bağlantısı kəsilib və ya düzgün işləmir.
Açar söndürülüb və ya həm PWR1, həm də PWR2 düzgün işləmir.
LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(STK LED-i yandıqda)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Göstəriş
Yanıb-sönür: açar düzgün işləyir. Yandırılır və ya Söndürülür: keçid düzgün işləmir.
Yaşıl Aktiv: Bütün fanatlar düzgün işləyir. Sarı Yandır: Bütün fanatlar düzgün işləmir.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Yaşıl Aktiv: 1000 Mbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 1000 Mbps sürətlə işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 10Mbps/100 Mbps sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 10Mbps/100 Mbps sürətlə işləyir və məlumat ötürür və ya qəbul edir. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
Aktivdir: Port nömrəsi yığın topologiyasındakı vahid identifikatorunu göstərir.
Yaşıl Aktiv: 10 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 10 Gbps-də işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 1 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 1 Gbps sürətlə işləyir və məlumat ötürür və ya alır. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Həm PWR1, həm də PWR2 düzgün işlədikdə və açar PWR1 tərəfindən gücləndikdə, PWR10 elektrik şəbəkəsindən ayrıldıqdan sonra LED PWR20 (sarı) sönməsi 2-2 saniyə çəkir.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Giriş
Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 Port
10G SFP+ Slot LED
S6500-48GP6XF-nin ön paneli aşağıdakı şəkildə göstərilmişdir.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 Port
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 Port
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 Port
25G SFP28 Slot LED
Giriş 03
Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 Port
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 Port
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST
Göstəriş
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Yanıb-sönür: açar düzgün işləyir. Yandırılır və ya Söndürülür: keçid düzgün işləmir.
Yaşıl Aktiv: Bütün fanatlar düzgün işləyir. Sarı Yandır: Bütün fanatlar düzgün işləmir.
Yandırılmış: Qalan PoE gücü 7 Vt-dır. Yanıb-sönən: Bu LED 7 dəqiqə yandıqdan sonra qalan PoE gücü 2 Vt saxlayır. Off: Qalan PoE gücü > 7 W-dir.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
04 Giriş
Omada Campus Stackable L3 Managed Switch
LED
Göstəriş
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
Yaşıl Aktiv: 1000 Mbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 1000 Mbps sürətlə işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 10Mbps/100 Mbps sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 10Mbps/100 Mbps sürətlə işləyir və məlumat ötürür və ya qəbul edir. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(STK LED-i yandıqda)
Aktivdir: Port nömrəsi yığın topologiyasındakı vahid identifikatorunu göstərir.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(PoE LED-i yandıqda)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Yaşıl Aktiv: 10 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 10 Gbps-də işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 1 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 1 Gbps sürətlə işləyir və məlumat ötürür və ya alır. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Giriş 05
Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
İdarəetmə limanı
LED
Console Port USB3.0 Port
(RJ45/Type-C)
Rejim seçimi
Düymə
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Rejimin Seçilməsi Düyməsi
İdarəetmə limanı
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
İdarəetmə limanı
LED
USB 3.0 portu
Konsol Portu
(RJ45/Type-C)
Rejimin Seçilməsi Düyməsi
25G SFP28 Yuvası
LED
(Port 1-24)
The front panel of S7500-48Y8C is shown as the following figure.
100G QSFP28 Slot (Port 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Giriş
100G QSFP28 Slot (Port 49-56)
Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Rejimin Seçilməsi Düyməsi
İdarəetmə Portu LED
USB 3.0 portu
Console Port (Type-C/RJ45)
100G QSFP28 yuvası
LED
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
SYS FAN
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(SPD LED-i yandıqda)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Göstəriş
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Yanıb-sönür: açar düzgün işləyir. Yandırılır və ya Söndürülür: keçid düzgün işləmir.
Yaşıl: Bütün fanatlar düzgün işləyir. Sarı: Bütün fanatlar düzgün işləmir.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Qeyd:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Yaşıl Aktiv: 10 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 10 Gbps-də işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 1 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 1 Gbps sürətlə işləyir və məlumat ötürür və ya alır. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Giriş 07
Omada Campus Stackable L3 Managed Switch
LED
Göstəriş
Port 27-32 of S7500-26XF6Y ***
(SPD LED-i yandıqda)
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Yaşıl Aktiv: 100 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Yaşıl yanıb-sönür: 100 Gbps-də işləyir və məlumat ötürür və ya alır. Sarı Aktiv: 40 Gbit/s sürətlə işləyir, lakin fəaliyyət yoxdur. Sarı yanıb-sönür: 40 Gbps sürətlə işləyir və məlumat ötürür və ya alır. Off: Heç bir cihaz müvafiq porta qoşulmayıb.
Qeyd:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(STK LED-i yandıqda)
Aktivdir: Port nömrəsi yığın topologiyasındakı vahid identifikatorunu göstərir.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Giriş
Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Model
1000M
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
Yuva
Yuva
Liman
Liman Limanı
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Qeyd: PWR1 əsas enerji təchizatıdır və PWR2-dən üstündür.
Giriş 09
Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Təhlükəsizlik Yuvası
LED
Topraklama Terminalı
Enerji təchizatı modulu
LED
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Topraklama Terminalı
LED
Power Supply Module Locking Strap Slot
LED
Kensington Təhlükəsizlik Yuvası
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
S7500-48Y8C-nin arxa paneli aşağıdakı şəkildə göstərilib. Şəkil yalnız nümayiş məqsədlidir. Açarınızın görünüşü təsvir ediləndən fərqli ola bilər.
Topraklama Terminalı
LED
LED
Kilidləmə kəməri
Yuva
Enerji təchizatı modulu
10 Giriş
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
LED LED
Locking Strap Slot
Power Supply Module Kensington Security Slot
Topraklama Terminalı
LED
Locking Strap Slot
Enerji təchizatı modulu
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Giriş 11
Omada Campus Stackable L3 Managed Switch
Fəsil 2 Quraşdırma
2.1 Paketin məzmunu
Paketdə aşağıdakı maddələrin olduğundan əmin olun. Əgər sadalanan əşyalardan hər hansı biri xarab və ya əskik olarsa, zəhmət olmasa distribyutorunuzla əlaqə saxlayın. Rəqəmlər yalnız nümayiş üçündür. Faktiki əşyalar təsvir ediləndən görünüşü və miqdarına görə fərqlənə bilər.
Keçid
Elektrik kabeli və konsol kabeli
Quraşdırma Bələdçisi
Biznes Şəbəkə Həlli
Quraşdırma Bələdçisi
Omada Campus Stackable L3 Managed Switch
Montaj mötərizələri, vintlər və rezin ayaqlar
2.2 Təhlükəsizlik tədbirləri
Cihazın düzgün istifadə edilməməsi nəticəsində yaranan hər hansı zədə və bədən xəsarətinin qarşısını almaq üçün aşağıdakı qaydalara əməl etməlisiniz.
Safety Precautions Keep the power off during the installation. Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is
well grounded. Use only the power cord provided with the switch. Make sure that the supply voltage arxa panelində göstərilən spesifikasiyalara uyğun gəlir
keçid. Açarın yaxşı havalandırılan bir mühitdə quraşdırıldığından və onun ventilyasiya çuxurunun olmadığından əmin olun
bloklanıb. Anahtarın qapağını açmayın və ya çıxarmayın. Cihazı təmizləməzdən əvvəl enerji təchizatını kəsin. Sulu parça ilə təmizləməyin və heç vaxt
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Sayt tələbləri
Temperatur/Rütubət
12 Quraşdırma
Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Açarda yığılan toz statik elektrik tərəfindən udula bilər və metal təmas nöqtələrinin zəif təması ilə nəticələnə bilər. Statik elektrikin qarşısını almaq üçün cihaz üçün bəzi tədbirlər görülüb, lakin çox güclü statik elektrik daxili dövrə lövhəsindəki elektron elementlərə ölümcül ziyan vura bilər. Statik elektrikin açarın işinə təsirinin qarşısını almaq üçün aşağıdakı maddələrə çox əhəmiyyət verin: Cihazı müntəzəm olaraq tozdan təmizləyin və daxili havanı təmiz saxlayın. Cihazı yaxşı torpaqlanmış saxlayın və statik elektrikin ötürüldüyünə əmin olun. Elektromaqnit müdaxiləsi
Cihazdakı kapasitans və endüktans daxil olmaqla elektron elementlər, tutumlu birləşmə, endüktans birləşməsi və empedans birləşməsi ilə həyata keçirilən emissiya kimi xarici müdaxilələrdən təsirlənə bilər. Müdaxilələri azaltmaq üçün aşağıdakı tədbirləri görməyinizə əmin olun: Elektrik şəbəkəsindən müdaxiləni effektiv şəkildə süzə bilən enerji təchizatı istifadə edin. Cihazı radio ötürücü kimi yüksək tezlikli və güclü cərəyanlı cihazlardan uzaq tutun
stansiya. Lazım olduqda elektromaqnit qoruyucudan istifadə edin. İldırımdan Mühafizə
Quraşdırma 13
Omada Campus Stackable L3 Managed Switch
Çox yüksək səstage cərəyanlar ildırım baş verdikdə dərhal yarana bilər və elektrik boşalma yolunda hava dərhal 20,000 °C-ə qədər qızdırıla bilər. Bu ani cərəyan elektron cihazları zədələyəcək qədər güclü olduğundan, ildırımdan daha təsirli mühafizə tədbirləri görülməlidir. Rafın və cihazın yaxşı torpaqlandığından əmin olun. Elektrik rozetkasının yerlə yaxşı təmasda olduğundan əmin olun. Ağlabatan bir kabel sistemi saxlayın və ildırımdan qaçın. Xaricdə naqil çəkərkən SPD siqnalından (Surge Protective Device) istifadə edin.
Note: For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Installation Site
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Quraşdırma alətləri
Phillips tornavida ESD-qoruyucu bilək qabığı Kabellər
Qeyd: Bu alətlər məhsulumuza daxil deyil. Lazım gələrsə, onları ayrıca satın ala bilərsiniz.
2.4 Məhsulun quraşdırılması
Keçid öndən arxaya istilik yayma xüsusiyyəti ilə hazırlanmışdır. İşlədikdə, hava aşağıda göstərildiyi kimi dövr edir. İstiliyin daha yaxşı yayılması üçün cihazı yaxşı havalandırılan bir yerə quraşdırın və cihazın ətrafında 5-10 sm boşluqlar buraxın.
14 Quraşdırma
Şəkil 2-1
Hava dövranı
Omada Campus Stackable L3 Managed Switch
Masaüstü Quraşdırma
Cihazı masaüstünə quraşdırmaq üçün addımları yerinə yetirin:
1. Cihazı bütün armaturlarla bütün çəkisini saxlayacaq qədər güclü bir düz səthə qoyun.
2. Yapışqan arxa kağızları rezin ayaqlardan çıxarın.
3. İş masasına qoyulan zaman sürüşməsinin qarşısını almaq üçün rezin ayaqları cihazın altına bağlayın.
Şəkil 2-2
Masaüstü Quraşdırma
Ayaqlar Cihazın Aşağı hissəsi Çəngəl
Rafın quraşdırılması
Paketə 6 cüt müxtəlif rəf montaj mötərizələri daxildir, onların şəkilləri aşağıda təsvir edilmişdir və faktiki məhsullardan fərqli ola bilər.
Şəkil 2-3
Montaj mötərizələri
Screw Hole Group 2
Bracket D Bracket C Bracket B Bracket A
Screw Hole Group 1
Screw Hole Group 3
Mötərizədə F
Screw Hole Group 4-2 (for device with 420mm depth)
Screw Hole Group 5
Vida deliyi
Qrup 4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Mötərizədə E
Quraşdırma 15
Omada Campus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Metod
Nümayiş
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Rack Distance
(For device with a depth of 380mm)
Rack Distance
(For device with a depth of 420mm)
Rack Distance
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 Quraşdırma
Omada Campus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Cihazı quraşdırmaq üçün aşağıda təsvir olunan təlimatlara əməl edin:
1. Attach the M6 nuts to the racks.
Şəkil 2-4
Securing M6 Nuts
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
Şəkil 2-5
Installing Brackets on Racks
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Quraşdırma 17
Omada Campus Stackable L3 Managed Switch
Şəkil 2-6
Installing Brackets on Switch
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
Şəkil 2-7
Installing Switch on Racks
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 Quraşdırma
Omada Campus Stackable L3 Managed Switch
Enerji təchizatı modulunun quraşdırılması
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
Şəkil 2-8
Appearance of the Power Supply Module
AC Elektrik Şnurunun Bağlayıcısı
FAN
Saxlayıcı kliplər
Extraction Handle
LED
Locking Strap Slot Release Handle
Daha bir enerji təchizatı modulu əlavə etmək lazımdırsa, lütfən, addımları yerinə yetirin:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
3. Release the extraction handle to fix the power supply module in place.
Şəkil 2-9
Enerji təchizatı modulunun quraşdırılması
Dəstəyi buraxın
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Quraşdırma 19
Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Enerji təchizatı modulunu çıxarmaq lazımdırsa, lütfən, addımları yerinə yetirin:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Ventilyator Modulunun Quraşdırılması
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Şəkil 2-11 Fan Modulunun Görünüşü
LED
20 Quraşdırma
Extraction Handle Retainer Clips Release Handle
Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
Şəkil 2-12 Zədələnmiş Fan Modulunun Çıxarılması
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Quraşdırma 21
Omada Campus Stackable L3 Managed Switch
Fəsil 3 Bağlantı
3.1 Ethernet Portu
Aşağıdakı şəkildə göstərildiyi kimi keçidin bir Ethernet portunu RJ45 kabeli ilə kompüterə qoşun.
Şəkil 3-1
RJ45 portunun qoşulması
RJ45 limanı
RJ45 Kabeli
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
Şəkil 3-2
Inserting the Fiber Module
Slot Fiber Module
3.3 Konsol Portu
CLI (Əmr Sətri İnterfeysi) sizə kommutatoru idarə etməyə imkan verir, beləliklə, kompüterləri və ya terminalları kabel vasitəsilə kommutatordakı konsol portuna qoşduqdan sonra CLI-ni yükləyə bilərsiniz (RJ45 konsol kabeli təmin edilir, Type-C kabeli isə təmin edilmir).
Aşağıdakı şəkildə göstərildiyi kimi cihazın RJ45 konsol portunu konsol kabeli ilə kompüterinizə qoşun.
22 Əlaqə
Şəkil 3-3
Konsolun (RJ45) Portunun qoşulması
Omada Campus Stackable L3 Managed Switch
Aşağıdakı şəkildə göstərildiyi kimi, cihazın Type-C konsol portunu Type-C kabeli (təmin edilməyib) ilə kompüterinizə qoşun.
Şəkil 3-4
Konsolun (USB) Portunun qoşulması
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Quraşdırmanı yoxlayın
Quraşdırmanı tamamladıqdan sonra aşağıdakı elementləri yoxlayın: Havalandırma üçün cihazın ətrafında 5-10 sm boşluq olmalıdır və hava axınına əmin olun.
adekvatdır. Cildtagenerji təchizatının e giriş həcminin tələbinə cavab verirtagcihazın e. Elektrik rozetkası, cihaz və rəf yaxşı torpaqlanıb. Cihaz digər şəbəkə cihazlarına düzgün qoşulub.
Əlaqə 23
Omada Campus Stackable L3 Managed Switch
3.5 Açılır
Aşağıdakı şəkildə göstərildiyi kimi, təchiz edilmiş elektrik kabelinin qadın konnektorunu cihazın elektrik rozetkasına qoşun və müsbət konnektoru elektrik rozetkasına qoşun. Əmin olun ki, cildtagenerji təchizatının e giriş həcminin tələbinə cavab verirtage (100-240 V~ 50/60 Hz).
Şəkil 3-5
Enerji təchizatına qoşulma
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 İnisiallaşdırma
Cihaz işə salındıqdan sonra, Açılış Özünü Sınamağa başlayır. Cihazın düzgün işləməsini təmin etmək üçün bir sıra testlər avtomatik olaraq həyata keçirilir. Bu müddət ərzində LED göstəriciləri aşağıdakı qaydada cavab verəcəkdir:
1. PWR LED göstəricisi hər zaman yanır. SYS LED və bütün limanların LED göstəriciləri sönür.
2. Təxminən bir dəqiqədən sonra bütün portların SYS LED və LED göstəriciləri bir anlıq yanıb-sönəcək və sonra sönəcək.
3. Bir neçə saniyə sonra SYS LED göstəricisi yanıb-sönəcək və bu da uğurlu başlanğıcın başlanğıcını göstərir.
3.7 Stack Topologiyası
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Keçid
Uyğun Model(lər)
Kəmiyyət
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 Əlaqə
Omada Campus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Fərqli ssenarilər üçün üç yığın topologiyası strukturu var, lütfən ehtiyaclarınıza uyğun olaraq düzgün topologiya qurun:
1. Zəncir Topologiyası: Zəncir topologiyası nisbətən sadədir və birinci və sonuncu bölmə arasında kabel bağlantısı tələb etmir. Uzun məsafəli yığma üçün uyğundur, lakin etibarlılığı nisbətən aşağıdır.
Şəkil 3-6
Zəncir topologiyası
Yığma Port Qrupu 2
Yığma Port Qrupu 1
…
2. Halqa topologiyası: Halqa topologiyası zəncir topologiyası ilə müqayisədə daha yüksək etibarlılığa malikdir. Halqa topologiyasındakı zəncirlərdən biri kəsildikdə, halqa topologiyası zəncir topologiyasına çevrilir, lakin bütün yığın sistemi yenə də normal işləyə bilər. Halqa topologiyası birinci və sonuncu qurğu arasında kabel bağlantısı tələb edir, ona görə də uzun məsafəli yığma üçün uyğun deyil.
Şəkil 3-7
Halqa topologiyası
Yığma Port Qrupu 2
Yığma Port Qrupu 1
…
Əlaqə 25
Omada Campus Stackable L3 Managed Switch
3. Ulduz Topologiyası: Ulduz topologiyası açarları mərkəzi əsas keçidə birləşdirir, buna görə də vahid idarəetməni təmin edərkən üzv keçidlər arasında məlumat ötürmə sürətini əhəmiyyətli dərəcədə artıra bilər.
Şəkil 3-8
Ulduz topologiyası
Yığma Port Qrupu 2
Yığma Port Qrupu 3
Yığma Port Qrupu 1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 Əlaqə
Omada Campus Stackable L3 Managed Switch
Fəsil 4 Konfiqurasiya
4.1 Konfiqurasiya Bitdiview
Şalter iki konfiqurasiya seçimini dəstəkləyir:
Bağımsız rejim: keçidi tək-tək konfiqurasiya edin və idarə edin. Nəzarətçi rejimi: şəbəkə cihazlarını mərkəzləşdirilmiş şəkildə konfiqurasiya edin və idarə edin. -də tövsiyə olunur
giriş nöqtələri, açarlar və şlüzlər kimi kütləvi qurğulardan ibarət geniş miqyaslı şəbəkə.
Qeyd: Keçid müstəqil rejimdən nəzarətçi rejiminə keçirildikdə, konfiqurasiyalar itir. Ətraflı məlumat üçün rəsmi şəxsimizin yükləmə mərkəzindəki əlaqədar sənədlərə baxın website: https://support.omadanetworks.com/product/.
4.2 Müstəqil rejim
Bağımsız rejimdə, GUI (Qrafik İstifadəçi İnterfeysi) və ya CLI (komanda xətti interfeysi) istifadə edərək keçidi konfiqurasiya etmək və idarə etmək üçün kompüterdən istifadə edin.
Şəkil 4-1
Müstəqil rejim üçün topologiya
Keçid
PC
GUI-dən istifadə
1. Şalterin idarəetmə səhifəsinə daxil olmaq üçün açar və kompüterin eyni alt şəbəkədə olduğundan əmin olun. Bir brauzer açın və ünvan sahəsinə keçidin IP ünvanını yazın, sonra Enter düyməsini basın.
If the switch obtains IP address from the DHCP server (typically a gateway), find the switch’s IP address on the DHCP server.
Əks təqdirdə, keçid idarəetmə səhifəsini işə salmaq üçün 192.168.0.1 standart IP ünvanını istifadə edin.
2. The first time you log in, set the username and password to better protect your network and devices. After that, the system will automatically redirect you back to the login interface to authenticate with the newly created credentials.
3. Uğurlu bir girişdən sonra əsas səhifə görünəcəkdir. Müvafiq funksiyaları konfiqurasiya etmək üçün yuxarı və sol tərəfdəki menyulara basa bilərsiniz.
Ətraflı konfiqurasiyalar üçün İstifadəçi Bələdçisinə və CLI Bələdçisinə baxın. Təlimatları rəsmi şəxsimizin yükləmə mərkəzində tapa bilərsiniz website: https://support.omadanetworks.com/product/.
CLI-dən istifadə CLI vasitəsilə keçidə daxil olmaq üçün Telnet və ya SSH bağlantısını qurun.
Konfiqurasiya 27
Omada Campus Stackable L3 Managed Switch
Anahtara daxil olmaq üçün konsol portundan istifadə edin. Konsol portundan istifadə edərkən, PC-də terminal emulyasiya proqramını işə salın (məsələn, Hyper Terminal) və terminal emulyasiya proqramını aşağıdakı kimi konfiqurasiya edin:
Baud Rate 38400 bps
Məlumat bitləri 8
Paritet Yoxdur
Stop bitləri 1
Axına Nəzarət Yoxdur
Ətraflı konfiqurasiyalar üçün İstifadəçi Bələdçisinə və CLI Bələdçisinə baxın. Təlimatları rəsmi şəxsimizin yükləmə mərkəzində tapa bilərsiniz website: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Nəzarətçi rejimi
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
Şəkil 4-2
Manage the network via Omada Pro Hardware Controller (C5300)
Gateway Switch
Omada Pro Hardware Controller (C5300) EAP
28 Konfiqurasiya
EAP
EAP
Müştərilər
Omada Campus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Find the IP address of the gateway. Open the command line on your PC and enter ipconfig. In the result list, find the Default Gateway, which is also the IP address of the gateway.
2. Başlayın a web browser and enter the IP address of the gateway. Log into the gateway’s web səhifə. Sonra MAC ünvanına uyğun olaraq idarəedicinizin IP ünvanını tapmaq üçün Şəbəkə > LAN > DHCP Müştəri Siyahısına keçin.
3. Kontrollerinizin IP ünvanını açmaq üçün ünvan çubuğuna daxil edin web səhifə.
4. On the Omada Pro Controller’s web səhifədə, sürətli quraşdırmanı tamamlamaq üçün sehrbazı izləyin.
5. Tez quraşdırmadan sonra giriş səhifəsi görünür. Yaratdığınız istifadəçi adı və parolu daxil edin və Daxil ol düyməsini klikləyin. Sonra siz nəzarətçini daha da konfiqurasiya edə bilərsiniz.
6. Cihazları uzaqdan idarə etmək istəyirsinizsə, növbəti addımları izləyin:
a. Kontrollerinizdə Bulud Girişinin aktiv olduğundan əmin olun. Varsayılan olaraq, Bulud Girişi aktivdir. Bulud LED-in yavaş-yavaş yanıb-söndüyünə əmin olun.
b. Başlayın a web brauzerinizi açın və ünvan çubuğuna https://omada.tplinkcloud.com daxil edin. Daxil olmaq üçün TP-Link ID və parolunuzu daxil edin. + Nəzarətçi əlavə et seçiminə klikləyin və nəzarət cihazınızı əlavə etmək üçün Hardware Controller seçin. Sonra nəzarətçini daha da konfiqurasiya edə bilərsiniz.
For more details, refer to the Installation Guide of C5300.
Omada Pro Proqram Nəzarətçisi vasitəsilə
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
Şəkil 4-3
Omada Pro Software Controller vasitəsilə şəbəkəni idarə edin
Gateway
Keçid
Nəzarətçi
Omada Pro Software Controller AP
AP
AP
running on the Host PC
Müştərilər
Konfiqurasiya 29
Omada Campus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web səhifə. Əgər belə deyilsə, Şəbəkəni İdarə etmək üçün Brauzeri işə salın klikləyin.
2. On the Omada Pro Controller’s web səhifədə, sürətli quraşdırmanı tamamlamaq üçün sehrbazı izləyin.
3. Tez quraşdırmadan sonra giriş səhifəsi görünür. Yaratdığınız istifadəçi adı və parolu daxil edin və Daxil ol düyməsini klikləyin. Sonra siz nəzarətçini daha da konfiqurasiya edə bilərsiniz.
4. Cihazları uzaqdan idarə etmək istəyirsinizsə, növbəti addımları izləyin:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web səhifəsində Bulud Girişini aktivləşdirmək və TP-Link ID-nizi bağlamaq üçün Parametrlər > Bulud Girişinə keçin. Əgər onu sürətli quraşdırmada quraşdırmısınızsa, bu addımı atlayın.
b. Başlayın a web brauzerinizi açın və ünvan çubuğuna https://omada.tplinkcloud.com daxil edin. Daxil olmaq üçün TP-Link ID və parolunuzu daxil edin. TP-Link ID-nizlə bağlı olan nəzarətçilərin siyahısı görünəcək. Sonra nəzarətçini daha da konfiqurasiya etmək üçün Başlat üzərinə klikləyə bilərsiniz.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Omada Pro Bulud Əsaslı Nəzarətçi vasitəsilə
Omada Pro Bulud Əsaslı Nəzarətçi proqram nəzarətçisinin kompüterə quraşdırılmasına ehtiyac olmadan yaxşı alternativdir.
Lisenziyalar əlavə olaraq alınmalıdır.
Şəkil 4-4
Omada Pro Bulud Əsaslı Nəzarətçi vasitəsilə şəbəkəni idarə edin
Omada Buludu
Gateway
Keçid
AP
AP
AP
AP
Müştərilər
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 Konfiqurasiya
Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official website: https://support.omadanetworks.com/product/.
Konfiqurasiya 31
Omada Campus Stackable L3 Managed Switch
Əlavə A Giderme
Q1. Şalterin istifadəçi adını və şifrəsini unutmuş olsam nə edə bilərəm?
1. PC-nin konsol portunu keçidin konsol portuna qoşun və terminal emulyasiya proqramını açın.
2. Gücü söndürün və açarı yenidən başladın. BootUtil menyusuna daxil olmaq üçün terminal emulyasiya proqramı tərəfindən göstərilən hərəkəti yerinə yetirin. Fəaliyyət məhsuldan məhsula fərqlənir. Mümkün tədbirlər aşağıda verilmişdir: · Avtomatik yükləməni dayandırmaq üçün istənilən düyməni basın. · BootUtil menyusuna daxil olmaq üçün CTRL-B düyməsini basın.
3. The bootUtil menu will be shown. Enter the number 6 to select the “Password recovery” option and enter Y to delete all the users and passwords. Then you can reset the username and password.
Q2. Why does the PWR LED work abnormally? The PWR/Power LED should be lit up when the power system works normally. If the PWR/Power LED worked abnormally, take the following steps:
1. Make sure that the power cable is connected properly, and the power contact is normal. 2. Make sure the voltagenerji təchizatının e giriş həcminin tələbinə cavab verirtage-nin
keçid.
Q3. Giriş edə bilməsəm nə etməliyəm web management page? Try the following:
1. Keçiddəki hər bir port LED-ini yoxlayın və Ethernet kabelinin düzgün qoşulduğundan əmin olun. 2. Kommutatorda başqa portu sınayın və Ethernet kabelinin uyğun olduğuna və normal işlədiyinə əmin olun. 3. Açarı söndürün və bir müddət sonra yenidən yandırın. 4. Kompüterinizin IP ünvanının keçidin alt şəbəkəsində təyin olunduğundan əmin olun. 5. Əgər siz hələ də konfiqurasiya səhifəsinə daxil ola bilmirsinizsə, keçidi zavod parametrlərinə yenidən qurun. Sonra
kompüterinizin IP ünvanı 192.168.0.x (“x” 2-dən 254-ə qədər istənilən rəqəmdir) və alt şəbəkə maskası 255.255.255.0 kimi təyin edilməlidir.
Q4. Why is the terminal emulation program not displaying correctly? Try the following:
1. Enerji təchizatının normal olduğundan və konsol kabelinin düzgün qoşulduğundan əmin olun. 2. Konsol kabelinin düzgün tip olub olmadığını yoxlayın. 3. Terminal emulyasiya proqramının parametrlərinin düzgün olduğundan əmin olun: saniyədə bitləri konfiqurasiya edin
38400 kimi, Məlumat bitləri 8, Paritet Yoxdur, Dayanma bitləri 1 və Axına nəzarət Yoxdur.
32 Appendix A Troubleshooting
Omada Campus Stackable L3 Managed Switch
Əlavə B Spesifikasiyalar
Specifications for S6500 Series Switches
Maddə
Məzmun
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Standartlar
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
Appendix B Specifications 33
Omada Campus Stackable L3 Managed Switch
PoE büdcəsi
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Operating Temperature & Altitude
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Saxlama temperaturu -40 °C - 70 °C (-40 °F - 158 °F)
Əməliyyat Rütubəti 10% - 90% RH Kondensasiya olunmur
Saxlama Rütubəti
5% - 90% RH Kondensasiya olunmur
34 Əlavə B Spesifikasiyalar
Omada Campus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Maddə
Məzmun
Standartlar
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
LED
Operating Temperature & Altitude
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Saxlama temperaturu -40 °C - 70 °C (-40 °F - 158 °F)
Əməliyyat Rütubəti 10% - 90% RH Kondensasiya olunmur
Saxlama Rütubəti
5% - 90% RH Kondensasiya olunmur
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Dəstəklənən hündürlük dəniz səviyyəsindən 5000 m-ə qədərdir. Qeyd etmək lazımdır ki, hündürlük 2000 m-dən yuxarı olduqda, hündürlüyün hər 220 metr artması ilə maksimum işləmə temperaturu 1°C (1.8°F) düşəcək.
Appendix B Specifications 35
Omada Campus Stackable L3 Managed Switch
Enerji təchizatı modulları üçün spesifikasiyalar
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Güc Girişi
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
Çıxış həcmitage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
Çıxış cərəyanı
9.35 A (Maksimum)
16.5 A (Maksimum)
45 A (Maksimum)
Çıxış Gücü
500 W (Maksimum)
900 W (Maksimum)
550 W (Maksimum)
Əməliyyat Hündürlüyü
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 Əlavə B Spesifikasiyalar
CE İşarəsi Xəbərdarlığı
Bu A sinif məhsuludur. Məişət mühitində bu məhsul radio müdaxiləsinə səbəb ola bilər, bu halda istifadəçidən adekvat tədbirlər görməsi tələb oluna bilər.
AB Uyğunluq Bəyannaməsi
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863. The original EU Declaration of Conformity may be found at https://www.tp-link.com/en/support/ce/
Böyük Britaniya Uyğunluq Bəyannaməsi
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK Declaration of Conformity may be found at https://www.tp-link.com/support/ukca/
, .
DİQQƏT:
İki qütblü, neytral ərimə. Xidmətdən əvvəl elektrik şəbəkəsini ayırın.
Təhlükəsizlik Məlumatı
· Cihazı sudan, yanğından, rütubətdən və ya isti mühitdən uzaq tutun. · Cihazı sökməyə, təmir etməyə və ya dəyişdirməyə çalışmayın. Əgər sizə xidmət lazımdırsa, bizimlə əlaqə saxlayın. · Cihazı alt səthi aşağıya doğru yerləşdirin. · Enerji təchizatı şnurunun ştepselindən ayırma cihazı kimi istifadə olunur, rozetka olmalıdır
easily accessible. · Plug the product into the wall outlets with earthing connection through the power supply cord
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
batareyalar.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Cihazı işləyərkən yuxarıdakı təhlükəsizlik məlumatlarını oxuyun və əməl edin. Biz cihazın düzgün istifadə edilməməsi nəticəsində heç bir qəza və ya zədənin baş verməyəcəyinə zəmanət verə bilmərik. Zəhmət olmasa bu məhsulu ehtiyatla istifadə edin və riski öz üzərinizə götürün.
Texniki dəstək, istifadəçi təlimatları və digər məlumat üçün https://support.omadanetworks.com/ saytına daxil olun və ya sadəcə QR kodunu skan edin.
© 2026 TP-Link 7100002759 REV2.0.1
Sənədlər / Resurslar
![]() |
Omada L3 Campus Stackable Managed Switch [pdf] İstifadəçi Təlimatı L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch |